  high precision, digital pressure switch series zse40/ise40 16-2-15 zse ise pse z i se3 ps z i se 1 2 zsp isa2 is zsm pf2 if data
anti-chattering function devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure. this function prevents such momentary pressure drops from being detected as abnormal pressures by allowing the response time selection to be changed. [selectable response times: t] 2.5 ms (normal), 24 ms, 192 ms or 768 ms the normal setting is selected when shipped from the factory. (operating principle) the pressure values measured within the user-selected response time are averaged, and switch output (on/off) is determined by comparing this averaged pressure value with the set pressure. pressure momentary change t (ms) t (ms) time time time (averaging) (averaging) set value switch output operation when normal on off switch output operation when anti-chattering function is used on off p1 p2 repeatability 0.2% f.s. 1 digit or less ip65 compatible dusttight/splash proof type a uto shift function erroneous operation may occur if there is fluctuation in the primary pressure. the auto shift function compensates for pressure changes to ensure proper on/off switch response during such fluctuations. (operating principle) at the point when the primary pressure fluctuates, the set pressure value is compensated by setting the auto shift input (external input) to low (no-voltage) input, using the pressure measured at that point as a standard. without using auto shift when the primary pressure fluctuates, a correct determination becomes impossible. when using auto shift time time time time time on off switch output 1, 2 hi lo a uto shift input 5 ms or more 10 ms or less switch output response time when auto shift is input. set value p1 p2 set value p1 p2 switch output 1, 2 on off pressure primary pressure normal primary pressure drop does not turn on does not turn off primary pressure increase primary pressure normal set value compensation set value compensation primary pressure drop primary pressure increase pressure [ ] high speed response: 2.5 ms or less with anti-chattering function stable switch output is possible even with sudden w ith auto shift function allows switch output unaffected by variations in primary pressure. 3 types of piping different piping methods are possible to accommodate the installation location. compound pressure (zse40f) able to detect suction pressure (vacuum pressure) and release pressure (positive pressure) with a single pressure switch. 16-2-16
16-2-17 zse ise pse z i se3 ps z i se 1 2 zsp isa2 is zsm pf2 if data series zse40/ise40 high precision, digital pressure switch how to order zse40 01 ise40 01 22 22 for vacuum/compound pressure for positive pressure 10.0 to ?01.3 kpa ?00.0 to 100.0 kpa set pressure range nil f ?.100 to 1.000 mpa f or positive pressure set pressure range nil unit specifications nil m with unit switching function note1) si unit only note 2) nil l lead wire length 0.6 m 3 m ? option npn open collector 2 outputs + analog output npn open collector 2 outputs + auto shift input pnp open collector 2 outputs + analog output pnp open collector 2 outputs + auto shift input input/output specifications 22 30 ? 62 ? 70 ? setting range ?00.0 to 100.0 kpa ?01.3 to 101.3 kpa ?.000 to 1.000 mpa set pressure range ?00.0 to 100.0 kpa 10.0 to ?01.3 kpa ?.1 to 1.000 mpa option nil a none bracket a (zs-24-a) b bracket b (zs-24-b) e p anel mount (zs-22-a) f p anel mount + front protective cover piping specifications 01: r 1/8 (with m5 female threads) t1: npt 1/8 (with m5 female threads) r 1/8, npt 1/8 m5 x 0.8 female threads ? m5: m5 x 0.8 (female threads) m5 x 0.8 ? c4: with ? one-touch fitting ? c6: with ? one-touch fitting w all mount wall mount ? option ?, ? one-touch fitting w1: rc 1/8 rc 1/8 reverse pressure two directions rc 1/8 f or vacuum pressure f or compound pressure note when equipped with auto shift function, the following ranges can be set. note 1) this will no longer be sold for use in j apan after the new weight and measure act is implemented (october,1999). note 2) fixed unit f or vacuum/compound pressure: kpa f or positive pressure: mpa (zs-24-c) ? when optional parts only are required, order with the part n umbers inside ( ).
16-2-18 series zse40/ise40 specifications example of internal circuit and wiring rated pressure range operating pressure range/set pressure range withstand pressure set pressure resolution note 1) applicable fluid po w er supply voltage current consumption switch output repeatability hysteresis response time (with anti-chattering function) output short circuit protection display display accuracy indicator light analog output note 2) a uto shift input note 3) environmental resistance t emperature characteristics port size lead wire w eight zse40f (compound pressure) ?00.0 to 100.0 kpa ?00.0 to 100.0 kpa 500 kpa 0.1 0.001 0.001 0.02 0.01 1 0.1 air, non-corrosive/non-flammable gas 12 to 24 vdc 10%, ripple (p-p) 10% or less 55 ma or less npn or pnp 2 outputs max. load current : 80 ma max. applied voltage: 30 vdc (with npn output) residual voltage : 1 v or less (with 80 ma load current) 0.2% f.s. 1digit or less var iable fixed (3 digits) note4) 2.5 ms or less (with anti-chattering function: 24 ms, 192 ms and 768 ms selections) ye s 3 1/2 digit led display (sampling cycle: 5 times/sec.) 2% f.s. 1 digit or less (at ambient temperature of 25 3 c) green led (out1: lights when on), red led (out2: lights when on) output voltage: 1 to 5 v 5% f.s. or less (in rated pressure range) linearity: 1% f.s. or less output impedance: approx. 1 k ? no-voltage input (reed or solid state), input 5 ms or more ip65 operating: 0 to 50?c, stored: ?0 to 60?c (no condensation or freezing) operating/stored: 35 to 85% rh (no condensation) 1000 vac for 1 min. between lead wires and body 50 m ? or more (at 500 vdc) between lead wires and body 10 to 500 hz at the smaller of amplitude 1.5 mm or acceleration 98 m/s 2 (10 g) in x, y, z directions for 2 hrs. each (de-energized) 980 m/s 2 (100 g) in x, y, z directions 3 times each (de-energized) in a temperature range of 0 to 50 c, 2% f.s. or less of pressure measured at 25 c 01: r 1/8, m5 x 0.8, t1: npt1/8, m5 x 0.8, w1: rc 1/8 c4: with ? one-touch fitting, c6: with ? one-touch fitting, m5: m5 female threads 5-wire oil resistant heavy-duty cord (0.15 mm 2 ) 01/t1 types approx. 60 g, w1 type approx. 80 g, c4/c6/m5 types approx. 92 g (each including 0.6 m lead wires) zse40 (vacuum pressure) 0.0 to ?01.3 kpa 10.0 to ?01.3 kpa output voltage: 1 to 5 v 2.5% f.s. or less (in rated pressure range) linearity: 1% f.s. or less output impedance: approx. 1 k ? ise40 (positive pressure) 0.000 to 1.000 mpa ?.100 to 1.000 mpa 1.5 mpa 0.001 0.01 0.01 0.1 kpa mpa k g f/cm 2 bar psi mmh g inh g hysteresis mode enclosure ambient temperature range ambient humidity range withstand voltage insulation resistance vibration resistance impact resistance window comparator mode setting range ?00.0 to 100.0 kpa ?01.3 to 101.3 kpa ?.000 to 1.000 mpa set pressure range ?00.0 to 100.0 kpa 10.0 to ?01.3 kpa ?0.1 to 1.000 mpa note) when equipped with auto shift function, the following ranges can be set. note 1) equipped with unit switching function (types without the unit switching function use si units (kpa or mpa) only.) note 2) for zse40 (f)/ise40- - 22 62 note 3) for zse40 (f)/ise40- - 30 70 note 4) for zse40f (compound pressure) with ?si indication, this is 0.03 to 0.04 psi. note 5) for zse40f (compound pressure) with ?si indication, zero clear is in the r ange of 0.01 psi. main circuit load load 1 k ? 12 to 24 vdc dc (+) (brown) analog output (gray) out1 (black) out2 (white) dc (? (blue) main circuit 1.2 k ? 6.8 k ? load load 12 to 24 vdc dc (+) (brown) a uto shift input (gray) out1 (black) out2 (white) dc (? (blue) zse40(f) ise40- -22(l)-(m) with analog output zse40(f) ise40- -62(l)-(m) with analog output zse40(f) ise40- -30(l)-(m) with auto shift input zse40(f) ise40- -70(l)-(m) with auto shift input main circuit 1 k ? 12 to 24 vdc dc (+) (brown) analog output (gray) out1 (black) out2 (white) dc (? (blue) main circuit 1.2 k ? 6.8 k ? load 12 to 24 vdc dc (+) (brown) a uto shift input (gray) out1 (black) out2 (white) dc (? (blue) load load load
kpa out2 out1 set description led (green) led (red) switches the mode and set value. down button set button displays present pressure. displays each mode. displays error mode. 3 1/2-digit led switching of the mode and set value up button calibration procedures setting procedure auto preset initial setting zero clear key lock mode normal operation set ?utput mode? ?esponse time?and ?uto or manual mode? enter the set value of the pressure to perform switch output. automatically sets the pressure for the adsorption confirmation or supply pressure confirmation. adjusts the zero point of the atmospheric pressure. allows fine-tuning of the data set automatically by auto preset. mode is not switched, even if the button is pressed during operation. measured pressure is displayed and the switch operation begins. displays out1 output condition when it is on, the led is illuminated. displays out2 output condition. when it is on, the led is illuminated. switches to each mode and fixes the set value. manual pressure setting manual pressure setting 16-2-19 zse ise pse z i se3 ps z i se 1 2 zsp isa2 is zsm pf2 if data series zse40/ise40 high precision, digital pressure switch
select the response time by pressing either  button or  button. ( ? 2.5 ms, ? ? 24 ms, ? 192 ms, ? 768 ms select among them.) press the ?et?button for more than 2 seconds until ? ?is displayed. release it when the display turns to ? ? calibration procedures initial setting unit mode: when using a product with a unit switching function, refer to the next page for unit-setting (for overseas). 1. initial condition mode 2. selection of output mode out1 3. selection of output mode out2 set press the ?et button. press the ?et button. press the ?et button. 4. selection of response time 5. setting auto/manual press the ?et button to complete the setting. set set set select the ?utput mode?for out1 by pressing either  but- ton or  button. ? ?normally open mode ? ?normally closed mode select ?uto preset mode?or ?anual set mode?by pressing either  button or  button. ? ?auto preset mode ? ?manual set mode select the ?utput mode?for out2 by pressing either  button or  button. ? ?normally open mode ? ?normally closed mode  button: increases set value  button: decreases set value displays the set values ? ? or ? ? alternately. ? only for zse40(f)/ise40- -30/70(l)-m, displays the input mode ? ?and the compensation value alternately. if auto shift input is not complete, zero is displayed. select the manual set mode in the initial condition mode and press the ?et?button until ? ? or ? ? is displayed. manual pressure setting output mode differs by the pressure set value. press the ?et button. 1. manual set mode 2. input set point value for out1 (1) 3. input set point value for out1 (2) set press the ?et button. press the ?et button. press the ?et button. 4. input set point value for out2 (1) 5. input set point value for out2 (2) set set set 6. display of setting auto shift press the ?et?button to complete the setting. set  button: increases set value  button: decreases set value displays the set values ? ? or ? ? alternately.  button: increases set value  button: decreases set value displays the set values ? ? or ? ? alternately.  button: increases set value  button: decreases set value displays the set values ? ? or ? ? alternately. 16-2-20 series zse40/ise40
prepare the equipment for use under operating conditions. when setting out1 is not required, press both the  b utton and  b utton simultaneously in this state to skip to ? ? select the auto preset mode in the initial setting mode and press the ?et button until ? is displayed. a uto preset (for adsorption confirmation) wo r kpiece 1 wo rk piece 2 wo r kpiece 1 wo r kpiece 2 wo r kpiece n on = a off = b + a ?b 4 a ?b 4 wo r kpiece n high v acuum max. a on off min. b atmosphere suction released max. a: max. pressure value when a workpiece is adsorbed. min. b: min. pressure value when a workpiece is not adsorbed. press the ?et button. 1. auto preset mode 2. preparation for auto preset 3. auto preset of out1 set press the ?et button. 4. preparation for auto preset press the ?et button. 5. auto preset of out2 press the ?et button to complete the setting. set set set repeat adsorption and non- adsorption release several times in this state. the optimal set value is determined automatically. supplies vacuum pressure, changing the condition of a wo r kpiece by adsorption nozzle, etc. when setting out2 is not required, press both the  b utton and  b utton simultaneously in this state to skip to the measurement mode. repeat adsorption and non- adsorption several times in this state. the optimum set value is determined automatically. unit set yes no yes no [p] [n] out1 output mode p-1 p-2 p-2 n-1 n-2 n-1 n-2 h h h h h (fixed hysteresis) = 3 digits h (fixed hysteresis) = 3 digits ? out2: same as out1. off on high pressure (for positive pressure/compound pressure) high vacuum (for vacuum pressure)  high pressure (for positive pressure/compound pressure) high vacuum (for vacuum pressure)  high pressure (for positive pressure/compound pressure) high vacuum (for vacuum pressure)  high pressure (for positive pressure/compound pressure) high vacuum (for vacuum pressure)  off on off on off on window comparator mode hysteresis mode window comparator mode output type p-1 unit selection out1: selection of the output mode press ?et?button. set it's only subject to zse40(f)/ise40- - (l). set the unit by either  button or  button. : kpa or mpa, : kgf/cm 2 , : bar, : psi, : inhg, : mmhg hysteresis mode 16-2-21 zse ise pse z i se3 ps z i se 1 2 zsp isa2 is zsm pf2 if data series zse40/ise40 high precision, digital pressure switch
prepare the equipment for use under operating conditions. when setting out1 is not required, press both the  b utton and  b utton simultaneously in this state to skip to ? ? select the auto preset mode in the initial setting mode and press the ?et button until ? is displayed. a uto preset (in the case of confirming the supply pressure) on point = c, c1 off point = c-3 digits, c1-3 digits (1 digit is the minimum setting unit.) on point (c, c1) off hysteresis (3 digits) press the ?et button. 1. auto preset mode 2. preparation for auto preset 3. auto preset of out1 set press the ?et button. 4. preparation for auto preset press the ?et button. 5. auto preset of out2 set set set prepare the equipment for use under operating conditions of out2. when setting out2 is not required, press both the  b utton and  b utton simultaneously in this state to skip to the measurement mode. the pressure is read and the optimal set value is determind automatically. the pressure is read and the optimal set value is determind automatically. press the ?et button for 4 seconds or longer. release it when the display turns to ? ? press the ?et button for 4 seconds or longer. release it when the display turns to ? ? display ? by pressing  b utton or  button. display ? by pressing  b utton or  button. calibration procedures other functions initiate key lock key lock mode release key lock set set p eak mode used to avoid a malfunction when buttons on the front part of the switch are pressed. bottom mode zero clear while displayed, pressing the  b utton for 1 second or longer causes the peak mode to display and blink. pressing the  button once again for 1 second or longer reinstates it. note) displaying the peak and the bottom display is not distinguished. pressing the  +  b uttons simultaneously with the supply pressure released to the atmosphere, causes it to reset to zero on the display and completes the zero clear operation. the function then returns to the measurement mode. while displayed, pressing the  b utton for 1 second or longer causes the bottom mode to display and blink. pressing the  button once again for 1 second or longer reinstates it. note) displaying the peak and the bottom display is not distinguished. allows an adjust to zero on the display if the pressure to be measured is within a range of 70 digits from the atmospheric pressure. press the ?et button to complete the setting. press the ?et button to complete the setting. press the ?et button to complete the setting. allows holding of the maximum pressure v alue on display under measurement. allows holding of the minimum pressure v alue on display under measurement. 16-2-22 series zse40/ise40
dimensions zse40(f)/ise40- 01 t1 mpa out2 out1 set atmospheric release port 30 30 600 (3000) lead wire length ?.5 18.35 6.4 2-m3 x 0.5 thread depth 4 m5 x 0.8 thread depth 5 width across flats 12 20 20 01: r 1/8 t1: npt 1/8 7.8 1.5 4.5 30 14 2.5 15.2 10.7 2.6 7 12.4 zse40(f)/ise40-w1 mpa out2 out1 set 30 30 600 (3000) lead wire length atmospheric release port 7 19 18.35 ?.5 6.4 rc 1/8 2-m4 x 0.7 thread depth 4 20 20 6.5 r rc 1/8 12 42 4 10.7 15.2 30 2.5 6 7.8 2.6 7 12.4 ? f or splash proof use (ip65), insert an air tube into the atmospheric release port. (refer to ?recautions on page 16-2-24 for details.) ? f or splash proof use (ip65), insert an air tube into the atmospheric release port. (refer to ?recautions on page 16-2-24 for details.) 16-2-23 zse ise pse z i se3 ps z i se 1 2 zsp isa2 is zsm pf2 if data series zse40/ise40 high precision, digital pressure switch
dimensions caution 1. immediately after supplying power, there is drift of about 0.5% f.s. when used with very low pressure, allow the unit to warm up for about 20 to 30 minutes. 2. do not use in locations where there is splashing or spraying of oils and solvents. 3. when using a commercially available switching regulator, be sure to ground the fg terminal. 4. in locations where the switch is exposed to water and dust, etc., these may enter the switch from the atmospheric release port. insert ? tubing (inside diameter ?.5) into the atmospheric release port, and extend the other end to a safe area where water, etc., is not splashed or sprayed. be sure that tubing is not bent and holes are not blocked, etc., or it will become impossible to make correct pressure measurements. air tube recommended tubing (smc) tu0425 (polyurethane) atmospheric release port f or m5 zse40 ( f ) /ise40 c4 c6 m5 precautions set out1 out2 mpa 600 (3000) lead wire length 32.3 44.3 28.15 22.15 20 30 30 2-4.5 atmospheric release port 6.4 25.4 12.8 8 ?.5 18.35 19 one-touch fitting ?, ? 7 12 43 2.5 30 15.2 10.7 7.8 2.6 7 12.4 m5 x 0.8 thread depth 5 8.5 mpa out2 out1 set ? f or splash proof use (ip65), insert an air tube into the atmospheric release port. (refer to ?recautions for details.) 16-2-24 series zse40/ise40
safety instructions these safety instructions are intended to prevent a hazardous situation and/or equipment damage. these instructions indicate the level of potential hazard by labels of "caution", "warning" or "danger" . to ensure safety, be sure to observe iso 4414 note 1) , jis b 8370 note 2) and other safety practices. 1. the compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. the expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. this person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2. only trained personnel should operate pneumatically operated machinery and equipment. compressed air can be dangerous if an operator is unfamiliar with it. assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed. 2. when equipment is to be removed, confirm the safety process as mentioned above. cut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3. before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc. 4. contact smc if the product is to be used in any of the following conditions: 1. conditions and environments beyond the given specifications, or if product is used outdoors. 2. installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. an application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. note 1) iso 4414: pneumatic fluid power--general rules relating to systems. note 2) jis b 8370: general rules for pneumatic equipment warning caution : operator error could result in injury or equipment damage. w arning : operator error could result in serious injury or loss of life. danger : in extreme conditions, there is a possible result of serious injury or loss of life. 16-14-3
1. confirm the specifications. products represented in this catalog are designed for use in compressed air appllications only (including vacuum), unless otherwise indicated. do not use the product outside their design parameters. please contact smc when using the products in applications other than compressed air (including vacuum). 4. use clean air if the compressed air supply is contaminated with chemicals, cynthetic materials, corrosive gas, etc., it may lead to break down or malfunction. selection mounting piping air supply maintenance operating environment w arning 1. instruction manual install the products and operate them only after reading the instruction manual carefully and understanding its contents. also keep the manual where it can be referred to as necessary. 2. securing the space for maintenance when installing the products, please allow access for maintenance. 3. tightening torque when installing the products, please follow the listed torque specifications. w arning 1. do not use in environments where the product is directly exposed to corrosive gases, c hemicals, salt water, water or steam. 2. do not expose the product to direct sunlight f or an extended period of time. 3. do not use in a place subject to heavy vibrations and/or shocks. 4. do not mount the product in locations where it is exposed to radiant heat. w arning 1. maintenance procedures are outlined in the operation manual. not following proper procedures could cause the product to malfunction and could lead to damage to the equipment or machine. 2. maintenance work if handled improperly, compressed air can be dangerous. assembly, handling and repair of pneumatic systems should be performed by qualified personnel only. 3. drain flushing remove drainage from air filters regularly. (refer to the specifications.) 4. shut-down before maintenance before attempting any kind of maintenance make sure the supply pressure is shut of and all residual air pressure is released from the system to be worked on. 5. start-up after maintenance and inspection apply operating pressure and power to the equipment and check for proper operation and possible air leaks. if operation is abnormal, please verify product set-up parameters. 6. do not make any modifications to be product. do not take the product apart. w arning 1. before piping make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. wrapping of pipe tape when screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping. also, when the pipe tape is used, leave 1.5 to 2 thread r idges exposed at the end of the threads. caution 1. operating fluid please consult with smc when using the product in applications other than compressed air (including vacuum). regarding products for general fluid, please ask smc about applicable fluids. 2. install an air dryer, aftercooler, etc. excessive condensate in a compressed air system may cause v alves and other pneumatic equipment to malfunction. installation of an air dryer, after cooler etc. is recommended. 3. drain flushing if condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines. if the drain bowl is difficult to check and remove, it is recommended that a drain bowl with the auto-drain option be installed. f or compressed air quality, refer to ?ir preparation equipment catalog. w arning common precautions be sure to read before handling. for detailed precautions on every series, refer to main text. 16-14-4
quality assurance information (iso 9001, iso 14001) reliable quality of products in the global market to enable our customers throughout the world to use our products with ev en greater confidence, smc has obtained certification for international standards ?so 9001 and ?so 14001? and created a complete structure for quality assurance and environmental controls. smc products pursue to meet its customers expectations while also considering companys contribution in society. this is an international standard for quality control and quality assurance. smc has obtained a large nu mber of certifications in japan and overseas, providing assurance to our customers throughout the world. quality management system iso 9001 this is an international standard related to environmental management systems and environmental inspections. while promoting environmentally friendly automation technology, smc is also making diligent efforts to preserve the environment. environmental management system iso 14001 sales coordination production make customers our first priority, offering them reliable and friendly service. market research product planning after service process control inspection, testing, etc. initial production control quality system education t raining of suppliers new product evaluation reliability design reliability testing new technical development education t raining research design development produce the highest quality with the participation of all employees. create new products using the latest technology, and offer the finest products in a timely manner. smcs quality control system quality policies quality control activities 16-14-5
ce mark smc product conforming to inter smc products complying with en/iso, csa/ul standards are supporting the ce mark indicates that machines and components meet essential requirements of all the ec directives applied. it has been obligatory to apply ce marks indicating conformity with ec directives when machines and components are exported to the member nations of the eu. once ? manufacturer himself?declares a product to be safe by means of ce marking (declaration of conformity by manufacturer), free distribution inside the member nations of the eu is permissible. ce mark smc provides ce marking to products to which emc and low voltage directives have been applied, in accordance with cetop (european hydraulics and pneumatics committee) guide lines. as of february 1998, the following 18 countries will be obliged to conform to ce mark legislation iceland, ireland, united kingdom, italy, austria, netherlands, greece, liechtenstein, sweden, spain, denmark, germany, norway, finland, france, belgium, portugal, luxembourg ec directives and pneumatic components ?machinery directive the machinery directive contains essential health and safety requirements for machinery, as applied to industrial machines e.g. machine tools, injection molding machines and automatic machines. pneumatic equipment is not specified in machinery directive. however, the use of smc products that are certified as conforming to en standards, allows customers to simplify preparation work of the technical construction file required for a declaration of conformity. electromagnetic compatibility (emc) directive the emc directive specifies electromagnetic compatibility. equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (ems/immunity) without emitting excessive electromagnetic affects (emi/emission). ?low voltage directive this directive is applied to products, which operate above 50 vac to 1000 vac and 75 vdc to 1500 vdc operating voltage, and require electrical safety measures to be introduced. ?simple pressure vessels directive this directive is applied to welded vessels whose maximum operating pressure (ps) and volume of vessel (v) exceed 50 bar/l. such vessels require ec type examination and then ce marking. 16-14-6
http://www.smcworld.com you to comply with ec directives and csa/ul standards. csa standards & ul standards ul and csa standards have been applied in north america (u.s.a. and canada) symbolizing safety of electric products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with electric products. both ul and csa standards are acknowledged in north america as the first class certifying body. they have a long experience and ability for issuing product safety certificate. products approved by csa or ul standards are accepted in most states and governments beyond question. since csa is a test certifying body as the national recognized testing laboratory (nrtl) within the jurisdiction of occupational safety and health administration (osha), smc was tested for compliance with csa standards and ul standards at the same time and was approved for compliance with the two standards. the above csa nrtl/c logo is described on a product label in order to indicate that the product is approved by csa and ul standards. tssa (mccr) registration products tssa is the regulation in ontario state, canada. the products that the operating pressure is more than 5 psi (0.03 mpa) and the piping size is bigger than 1 inch. fall into the scope of tssa regulation. products conforming to ce standard with ce symbol for simple visual recognition in this catalog each accredited product series is indicated with a ce mark symbol. however, in some cases, every available models may not meet ce compliance. please visit our web site for the latest selection of available models with ce mark. mark of compliance for csa mark of compliance for csa/ul national standards 16-14-7 smc product conforming to international standards
america europe u.s.a. smc corporation of america 3011 north franklin road indianapolis, in 46226, u.s.a. tel: 317-899-4440 fax: 317-899-3102 canada smc pneumatics (canada) ltd. 6768 financial drive mississauga, ontario, l5n 7j6 canada tel: 905-812-0400 fax: 905-812-8686 mexico smc corporation (mexico), s.a. de c.v. carr. silao-trejo k.m. 2.5 s/n, predio san jose del duranzo c.p. 36100, silao, gto., mexico tel: 472-72-2-55-00 fax: 472-72-2-59-44/2-59-46 chile smc pneumatics (chile) s.a. av. la monta?a 1,115 km. 16,5 p. norte parque industrial valle grande, lampa santiago, chile tel: 02-270-8600 fax: 02-270-8601 argentina smc argentina s.a. teodoro garcia 3860 (1427) buenos aires, argentina tel: 011-4555-5762 fax: 011-4555-5762 bolivia smc pneumatics bolivia s.r.l. avenida beni numero 4665 santa cruz de la sierra-casilla de correo 2281, bolivia tel: 591-3-3428383 fax: 591-3-3449900 venezuela smc neumatica venezuela s.a. apartado 40152, avenida nueva granada, edificio wanlac, local 5, caracas 1040-a, venezuela tel: 2-632-1310 fax: 2-632-3871 peru (distributor) impeco automatizacion industrial s.a. av. canevaro 752, lince, lima, peru tel: 1-471-6002 fax: 1-471-0935 uruguay (distributor) bako s.a. galicia 1650 esq. gaboto c.p. 11200, montevideo, uruguay tel: 2-401-6603 fax: 2-409-4306 brazil smc pneumaticos do brasil ltda. rua. dra. maria fidelis, nr. 130, jardim piraporinha-diadema-s.p. cep: 09950-350, brasil tel: 11-4051-1177 fax: 11-4071-6636 colombia (distributor) airmatic ltda. calle 18 69-05 apart. aereo 081045 santa fe de bogot?, colombia tel: 1-424-9240 fax: 1-424-9260 u.k. smc pneumatics (u.k.) ltd. vincent avenue, crownhill, milton keynes, mk8 0an, backinghamshire, u.k. tel: 01908-563888 fax: 01908-561185 germany smc pneumatik gmbh boschring 13-15 d-63329 egelsbach, germany tel: 06103-4020 fax: 06103-402139 italy smc italia s.p.a. via garibaldi 62 i-20061 carugate milano, italy tel: 02-9271365 fax: 02-9271365 france smc pneumatique s.a. 1 boulevard de strasbourg, parc gustave eiffel, bussy saint georges, f-77600 marne la vallee cedex 3 france tel: 01-64-76-10-00 fax: 01-64-76-10-10 sweden smc pneumatics sweden ab ekhagsv?gen 29-31, s-141 05 huddinge, sweden tel: 08-603-07-00 fax: 08-603-07-10 switzerland smc pneumatik ag dorfstrasse 7, postfach 117, ch-8484 weisslingen, switzerland tel: 052-396-3131 fax: 052-396-3191 austria smc pneumatik gmbh (austria) girakstrasse 8, a-2100 korneuburg, austria tel: 0-2262-6228-0 fax: 0-2262-62285 spain smc espa?a, s.a. zuazobidea 14 pol. ind. j?ndiz 01015 vitoria, spain tel: 945-184-100 fax: 945-184-510 ireland smc pneumatics (ireland) ltd. 2002 citywest business campus, naas road, saggart, co. dublin, ireland tel: 01-403-9000 fax: 01-466-0385 netherlands (associated company) smc pneumatics bv de ruyterkade 120, nl-1011 ab amsterdam, netherlands tel: 020-5318888 fax: 020-5318880 greece (distributor) s.parianopoulos s.a. 7, konstantinoupoleos street 11855 athens, greece tel: 01-3426076 fax: 01-3455578 denmark smc pneumatik a/s knudsminde 4 b dk-8300 odder, denmark tel: 70252900 fax: 70252901 smc? global service network 16-14-20
europe finland smc pneumatics finland oy pl72, tiistinniityntie 4, sf-02231 esp00, finland tel: 09-8595-80 fax: 09-8595-8595 norway smc pneumatics norway a/s vollsveien 13c, granfoss n?ingspark n-1366 lysaker, norway tel: 67-12-90-20 fax: 67-12-90-21 belgium (distributor) smc pneumatics n.v./s.a. nijverheidsstraat 20 b-2160 wommelgem belguim tel: 03-355-1464 fax: 03-355-1466 poland smc industrial automation polska sp.z.o.o. ul. konstruktorska 11a, pl-02-673 warszawa, poland tel: 022-548-5085 fax: 022-548-5087 turkey (distributor) entek pn?matik san.ve tic. ltd. sti perpa tic. merkezi kat:11 no.1625 80270 okmeydani istanbul, t?rkiye tel: 0212-221-1512 fax: 0212-221-1519 russia smc pneumatik llc. 36/40 sredny prospect v.o. st. petersburg 199004, russia tel: 812-118-5445 fax: 812-118-5449 czech smc industrial automation cz s.r.o. hudcova 78a, cz-61200 brno, czech republic tel: 05-4121-8034 fax: 05-4121-8034 hungary smc hungary ipari automatiz?l?si kft. budafoki ut 107-113 1117 budapest tel: 01-371-1343 fax: 01-371-1344 romania smc romania s.r.l. str. frunzei, nr. 29, sector 2, bucharest, romania tel: 01-3205111 fax: 01-3261489 slovakia smc priemyseln? automatiz?ci?, s.r.o nova 3, sk-83103 bratislava tel: 02-4445-6725 fax: 02-4445-6028 slovenia smc industrijska avtomatilca d.o.o. grajski trg 15, slo- 8360 zuzemberk, slovenia tel: 07388-5240 fax: 07388-5249 south africa (distributor) hyflo southern africa (pty.) ltd. p.o.box 240 paardeneiland 7420 south africa tel: 021-511-7021 fax: 021-511-4456 egypt (distributor) saadani trading & ind. services 15 sebaai street, miami 21411 alexandria, egypt tel: 3-548-50-34 fax: 3-548-50-34 oceania/asia australia smc pneumatics (australia) pty.ltd. 14-18 hudson avenue castle hill nsw 2154, australia tel: 02-9354-8222 fax: 02-9894-5719 new zealand smc pneumatics (new zealand) ltd. 8c sylvia park road mt.wellington auckland, new zealand tel: 09-573-7007 fax: 09-573-7002 taiwan smc pneumatics (taiwan) co.,ltd. 17, lane 205, nansan rd., sec.2, luzhu-hsiang, taoyuan-hsien, taiwan tel: 03-322-3443 fax: 03-322-3387 hong kong smc pneumatics (hong kong) ltd. 29/f, clifford centre, 778-784 cheung, sha wan road, lai chi kok, kowloon, hong kong tel: 2744-0121 fax: 2785-1314 singapore smc pneumatics (s.e.a.) pte. ltd. 89 tuas avenue 1, jurong singapore 639520 tel: 6861-0888 fax: 6861-1889 philippines shoketsu smc corporation unit 201 common goal tower, madrigal business park, ayala alabang muntinlupa, philippines tel: 02-8090565 fax: 02-8090586 malaysia smc pneumatics (s.e.a.) sdn. bhd. lot 36 jalan delima1/1, subang hi-tech industrial park, batu 3 40000 shah alam selangor, malaysia tel: 03-56350590 fax: 03-56350602 south korea smc pneumatics korea co., ltd. woolim e-biz center (room 1008), 170-5, guro-dong, guro-gu, seoul, 152-050, south korea tel: 02-3219-0700 fax: 02-3219-0702 china smc (china) co., ltd. 7 wan yuan st. beijing economic & technological development zone 100176, china tel: 010-67882111 fax: 010-67881837 thailand smc thailand ltd. 134/6 moo 5, tiwanon road, bangkadi, amphur muang, patumthani 12000, thailand tel: 02-963-7099 fax: 02-501-2937 india smc pneumatics (india) pvt. ltd. d-107 to 112, phase-2, extension, noida, dist. gautaim budh nagar, u.p. 201 305, india tel: (0120)-4568730 fax: 0120-4568933 indonesia (distributor) p.t. riyadi putera makmur jalan hayam wuruk komplek glodok jaya no. 27-28 jakarta 11180 indonesia tel: 021-625 5548 fax: 021-625 5888 pakistan (distributor) jubilee corporation first floor mercantile centre, newton road near boulton market p.o. box 6165 karachi 74000 pakistan tel: 021-243-9070/8449 fax: 021-241-4589 israel (distributor) baccara automation control kvutzat geva 18915 israel tel: 04-653-5960 fax: 04-653-1445 saudi arabia (distributor) assaggaff trading est. p.o. box 3385 al-amir majed street, jeddah-21471, saudi arabia tel: 02-6761574 fax: 02-6708173 16-14-21 smcs global service network


▲Up To Search▲   

 
Price & Availability of ISE40-T1-22

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X